FIRMWARE RELEASE NOTE ===================== Products affected: Q6052 Release date: 2018-05-02 Release type: Production Firmware version: 8.20.1 Preceding release: 8.10.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/tecnical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. New features in 8.20.1 ================================================================================ 8.20.1:F1 The possibility to edit scripts in camera has been disabled per default in order to increase minimum cyber security level. 8.20.1:F2 Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were recorded. 8.20.1:F3 Changed the default audio bitrate to 32 kbps. 8.20.1:F4 Updated AXIS Video Motion Detection to version 4.2.1. 8.20.1:F5 Changed the default input audio gain from 30 dB to 45 dB. 8.20.1:F6 Updated NTP server (openntpd) to version 6.2p3. 8.20.1:F7 Updated Fence- and Motion-Guard to version 2.1 with support for burnt-in alarm overlay support. 8.20.1:F8 Added support for showing hidden resolutions via API. The parameter Properties.Image.ShowSuboptimalResolutions has been added which will, when enabled, show all of the products supported resolutions. Features in 8.10.1 ================================================================================ 8.10.1:F1 VMD (Video Motion Detection) is updated to version 4.2. Corrections in 8.20.1 ================================================================================ 8.20.1:C1 Corrected an issue that made it necessary for the user to refresh manually the storage configuration page in the web-interfce to be updated e.g. when a storage has been disconnected from the camera. 8.20.1:C2 Corrected an issue that caused the camera to stop streaming in rare occasions. 8.20.1:C3 Corrected an issue that reported the camera to have PAL resolutions even for the NTSC version. 8.20.1:C4 Corrected an issue that made it necessary to login twice when connecting to the web-interface using Microsoft Edge. 8.20.1:C5 Corrected an issue that prevented trigger data to be inserted in every I-frame and when motion detection triggers. 8.20.1:C6 Corrected an issue when testing multiple email recipients. 8.20.1:C7 Corrected an issue where e-mail recipients could be wrongly formatted. 8.20.1:C8 Corrected an issue that prevented the user from taking image snapshots in H264 when using the Safari web browser. 8.20.1:C9 Corrected an issue that prevented the use of the whole sensor width for some aspect ratios. 8.20.1:C10 Corrected an issue that could cause synchronization to AVHS to fail. 8.20.1:C11 Corrected critical vulnerability ACV-128401. 8.20.1:C12 Corrected an issue with the AXIS event handler registration for ADP partners. 8.20.1:C13 Corrected an issue that caused the camera to become unreachable via link local address in the network when connecting client was in another subnet. Corrections in 8.10.1 ================================================================================ 8.10.1:C1 Corrected an issue with MJPEG images becoming corrupted in rare occasions. 8.10.1:C2 Corrected security vulnerability CVE-2017-9798. 8.10.1:C3 Corrected an issue when creating user accounts in Microsoft Edge 38 or IE 11. 8.10.1:C4 Corrected an issue that could cause noise in images in rare occasions. Known Bugs/Limitations ================================================================================ 8.20.1:L1 When downgrading a firmware the static IP configuration is lost. Axis recommends to perform a factory reset after downgrading. 8.20.1:L2 When performing a firmware rollback to a version older than 5.90 the database on an SD-card or the network share will be incompatible and it needs to be reformatted. 8.20.1:L3 When using an iOS device and Chrome or Safari web browser it is not possible to switch from viewer to administrator or operator. 8.20.1:L4 It is not possible to update the product using Genetec 5.7 SR2. Genetec will provide a patch in 5.7 SR3. 8.20.1:L6 Zooming via mouse scroll does not work in 8.20.1 release. Factory default or update to higher firmware, when available, is recommended. 8.10.1:L1 It is not possible to receive audio encoding details in the browser stream information. 8.10.1:L2 A user might experience frame drops in rare conditions when video streaming in Firefox 57 due to specific computer hardware. It is recommended to use Google Chrome instead. 8.10.1:L3 When performing a firmware rollback to a version older than 5.90 the database on an SD-card or the network share will be incompatible and it needs to be reformatted. 8.10.1:L4 When the camera is restored, the time zone is not saved meaning that it will be set to GMT 0. Supported AXIS VAPIX API Image Resolutions for Q6052 ================================================================================ Resolution Exceptions ========== ========== D1 720x576 2) 4) 720x480 3) 5) 4CIF 704x576 2) 4) 704x480 3) 5) 2CIF 704x288 2) 4) 704x240 3) 5) CIF 352x288 2) 4) 352x240 3) 5) QCIF 176x144 2) 4) 176x120 3) 5) D1 720x576 1) 2) 4) 720x480 1) 3) 5) 4CIF 704x576 1) 2) 4) 704x480 1) 3) 5) 2CIF 704x288 1) 2) 4) 704x240 1) 3) 5) CIF 352x288 1) 2) 4) 352x240 1) 3) 5) QCIF 176x144 1) 2) 4) 176x120 1) 3) 5) analyze 1) 1) Not visible in web user interface 2) PAL mode resolution 3) NTSC mode resolution 4) 960x720p50 5) 960x720p60