FIRMWARE RELEASE NOTE ===================== Products affected: AXIS Q6052 Release date: 2017-06-15 Release type: Production Firmware version: 7.20.1 File name: Q6052_7_20_1.bin Preceding release: 7.10.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New features in 7.20.1 since 7.10.1 ====================================================================== 7.20.1:F1 The functionality of enabling Axis DNS Service via control button has been disabled by default. It can be enabled again using VAPIX. 7.20.1:F2 Changed the default web server authentication from Basic & Digest to Digest only. 7.20.1:F3 Upon a factory default, the camera will generate a self-signed certificate at boot and enable HTTPS. This allows clients to use encrypted access from start. If HTTPS is to be used in daily operations, it is recommended to replace the generated self-signed certificate with a CA-signed certificate. 7.20.1:F4 Apache web server has been updated to version 2.4.25. 7.20.1:F5 Support for 24bit LPCM audio mode. 7.20.1:F6 OpenSSL has been updated to version 1.0.2k to increase overall minimum cyber security level. 7.20.1:F7 Products can list now all the supported auxiliary commands such as PTZ Test, Calibration, Speed Dry for clients asking for http:///axis- cgi/com/ptz.cgi?query=auxiliary. 7.20.1:F8 PTZ products can be controlled now via HTTP 1.1 keep-alive connections which increases PTZ control accuracy, reduces overhead communication and therefore lowers the risk for security focused network infrastructure to block PTZ control commands when controlling a PTZ camera. 7.20.1:F9 Support for AXIS SD card health API. The SD card health API allows a client to track and request the health and wear-out state of an camera with AXIS Surveillance SD Card. 7.20.1:F10 The Axis Media Control (AMC) is not longer embedded in the product and needs to be downloaded separately on https://www.axis.com/global/en/support/downloads /axis-media-control if needed. The Java Applet has been removed as well. 7.20.1:F11 Pressing "Download the server report" in System -> Maintenance will now automatically attach a snapshot of the image to the .zip file in order to simplify support. New features in 7.10.1 since 6.25.1.1 ====================================================================== 7.10.1:F1 Our ONVIF implementation have been improved by adding GetVideoEncoderConfigurationOptions extension. This makes it possible for an ONVIF client to get the bitrate range. 7.10.1:F2 It is now possible to specify image rotation via ONVIF video source configuration 7.10.1:F3 OpenSSL version updated to 1.0.2j. 7.10.1:F4 VMD upgraded to version 4.1. 7.10.1:F5 Corrected Turkey/Istanbul timezone from GMT+2 to GMT+3. 7.10.1:F6 New web-interface with improved usability and broader support of web-clients and operating systems. For more information please see https://www.axis.com/global/en/support/technical-notes/browser-support. 7.10.1:F7 The new web-interface supports 12 different pre-installed languages which will be chosen automatically based on browser settings. Uploading individual language files is not needed anymore. Supported Languages: English - German - French - Spanish - Italian - Portugese - Polish - Russian - Japanese - Chinese (Mainland) - Chinese (Taiwan) - Korean 7.10.1:F8 If Network Share is setup to use DNS host name as host and if the IP address changes after mount, the host name is resolved to current IP address. 7.10.1:F9 Added support for ONVIF standardised I/O events. 7.10.1:F10 Improved handling of EIS (Electronic Image Stabilization) during pan and tilt movements. 7.10.1:F11 Adjustable zoom speed can now be enabled/disabled in PTZ Advanced settings. Only applicable for products with various zoom speeds. 7.10.1:F12 Added a new parameter "AutoFocusSensitivity" in ImageSource I0 Sensor. Products autofocus sensitivity can be adjusted to either Low/Medium/High/Very High. 7.10.1:F13 Enhanced Recovery is now available as feature in Camera Settings offering Highlights Recovery or Shadows Recovery. Highlights Recovery improves the image appearance by decreasing brightness to the bright parts of the image whereas Shadows Recovery improves the image appearance by increasing brightness to the dark parts of the image. 7.10.1:F14 Corrected behavior for conditional triggers. 7.10.1:F15 Focus recall can create virtual three-dimensional zones in space around the camera where a fixed focus setting is applied when the camera enters the zone using pan, tilt or zoom. 7.10.1:F16 Improved Axis Zipstream technology for PTZ cameras. 7.10.1:F17 Improved handling for networks with small MTU values. 7.10.1:F18 Improved Zipstream using dynamic frame rate. 7.10.1:F19 Support for ONVIF Profile G. 7.10.1:F20 Introducing a new parameter "OverrideEflip" when enabled will the camera not perform Eflip. 7.10.1:F21 Axis Zipstream enabled. Corrections in 7.20.1 since 7.10.1 ====================================================================== 7.20.1:C1 Corrected Turkey/Istanbul timezone from GMT+2 to GMT+3. 7.20.1:C2 Corrected an issue that prevented the user from saving a action rule with a Email Recipient that had SSL enabled. 7.20.1:C3 Corrected a issue resulting in "503 Service Unavailable" when trying to play a recording from a camera with a specific time range via ONVIF. 7.20.1:C4 Corrected an issue with an additional sign "/" in the absolute upload path of an SFTP Recipient when saving the action rule causing it to not work correctly. 7.20.1:C5 Corrected an issue when an ONVIF client connected to the camera via digest authentication. 7.20.1:C6 Fixed critical vulnerability ACV-116267. 7.20.1:C7 Improved camera stability when recording via ONVIF profile G. Corrections in 7.10.1 since 6.25.1.1 ====================================================================== 7.10.1:C1 Improved performance when triggerdata enabled in plain config and when no motion windows have been created. 7.10.1:C2 Corrected handling of #D text overlay, it's no longer needed to specify the camera source. 7.10.1:C3 Improvements in session ID handling for rtsp streaming. Useful when streaming in some video clients. 7.10.1:C4 Added link local IPV6 support for NTP. 7.10.1:C5 Fixed Security vulnerability CVE-2016-5195. 7.10.1:C6 Improved handling of day and night shift levels adjustment. 7.10.1:C7 Improved HTTP image upload stability in unstable networks. 7.10.1:C8 Improved camera stability when metadata is used. 7.10.1:C9 Improved loading of the web-interface in unstable networks. 7.10.1:C10 Improved camera stability when TriggerData is used. 7.10.1:C11 Corrected a bug in the event system that prevented the camera from re-sending the SMTP notification every 10 seconds in case the receiving server reported an error. 7.10.1:C12 Fixed script error when naming a privacy mask with едц. 7.10.1:C13 Corrected possibility to include SPS (Sequence Parameter Set) and PPS (Picture Parameter Set) in the stream according to ACAP documentation. 7.10.1:C14 Fixed issues with that Guard Tours are running but are shown as a "undefined" state. 7.10.1:C15 Corrected inverted PT-head movements when using ONVIF. 7.10.1:C16 Fixed security vulnerability CVE-2015-7547. 7.10.1:C17 Fixed issues with stopped events for manual triggered recording. 7.10.1:C18 Date format now displayed correctly in ACM. 7.10.1:C19 Improved focus stability 7.10.1:C20 Optimized Network Share polling frequency. 7.10.1:C21 Improved stability in actionengine (tcp notification). Known Bugs/Limitations ====================================================================== 7.20.1:L1 Recording streams to SD Card with total bit rate above 12Mbit/sec may cause missing frames/sequences. 7.20.1:L2 The following features in Settings -> System will be displayed in English only as for now: Certificates, ONVIF, HTTPS, IEEE 802.1x, SNMP, Events, Stream profiles and Detectors. The current chosen language will not have any affect there. 7.20.1:L3 It is recommended to perform a factory default after downgrading the cameras firmware if needed. 7.20.1:L4 Features currently explained in the help files may not be supported in the camera. 7.20.1:L5 Video streaming H.264 for Safari has been temporarily disabled in the web- interface because of an bug in the Safari browser. 7.20.1:L6 No audio support when viewing MJPEG video streams directly in the web-interface. However, a recorded video MJPEG video stream from the cameras storage can be played with audio using a 3rd party client e.g. Microsoft Windows Media Player. 7.20.1:L7 It is recommended to refresh the browser page (F5) when a OSDI zone is deleted as the control buttons (Add, Modify, Enable/Disable, Remove) will disappear after doing so. 7.20.1:L8 Camera is not inserting a new I-frame when a 2nd client requests a video stream via multicast through RTSP which results in additional waiting time before video streaming starts. 7.20.1:L9 Videos that have been recorded using the video capture feature in live view may not be playable in some media players (e.g. VLC) as it is in an fragmented MP4 format without total video duration. 7.10.1:L1 Parts of the web-interface will have only English as language. Supported AXIS VAPIX API Image Resolutions for AXIS Q6052 ========================================================= Resolution Exceptions ========== ========== D1 720x576 2) 4) 720x480 3) 5) 4CIF 704x576 2) 4) 704x480 3) 5) 2CIF 704x288 2) 4) 704x240 3) 5) CIF 352x288 2) 4) 352x240 3) 5) QCIF 176x144 2) 4) 176x120 3) 5) analyze 1) 1) Not visible in web user interface 2) PAL mode resolution 3) NTSC mode resolution 4) 960x720p50 5) 960x720p60