FIRMWARE RELEASE NOTE ===================== Products affected: Q1941-E PT MOUNT Release date: 2019-02-15 Release type: Production Firmware version: 9.10.1 Preceding release: 8.50.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/tecnical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. New features in 9.10.1 ================================================================================ 9.10.1:F1 The following legacy VAPIX parameter have been removed due to non-usage: Network.DHCP.Fqdn Network.DHCP.IPCheckEnabled Network.DHCP.Retries Network.DHCP.StoreIPAddresseth0 Network.DHCP.StoreIPAddresseth1 Network.DHCP.Timeout 9.10.1:F2 Updated Video Motion Detection to version 4.3.3. 9.10.1:F3 Updated Motion Guard and Fence Guard to version 2.1.7. 9.10.1:F4 Upgraded Apache to version 2.4.37 to increase overall minimum cyber security level. 9.10.1:F5 Firwmare Recovery will also rollback the previous state of applications (ACAPs) now. Corrections in 9.10.1 ================================================================================ 9.10.1:C1 Corrected an issues that could cause an incorrect error message when testing HTTP recipient. 9.10.1:C2 Increased the character limit for certificate IDs from 32 to 128 characters. 9.10.1:C3 Corrected an issue that caused RTSP client timeout to be delayed. 9.10.1:C4 Corrected an issue that caused an HTTP-recipient based action rule to fail when the response from the server excluded the textual phrase (Example: HTTP 200). This will work now. 9.10.1:C5 Corrected an issue that caused the temperature information delivered via SNMP OID to be corrupted. Known Bugs/Limitations ================================================================================ 9.10.1:L1 It is recommended to perform firmware recovery to rollback the products firmware to a previous version. Downgrading the products firmware through the usual firmware upgrade process can cause configuration and ACAP loss. It is recommended to perform a factory default afterwards. 9.10.1:L2 The VAPIX Parameter Network.RTSP.AllowClientTransportSettings in PlainConfig -> Network needs to be set to "yes" before video can be streamed via ONVIF multicast. Supported AXIS VAPIX API Image Resolutions for Q1941-E PT MOUNT ================================================================================ Resolution Exceptions ========== ========== 768x576 720x576 640x512 640x480 480x360 384x288 320x256 320x240 240x180 176x144 160x128 160x120 704x576 1) 704x480 1) 704x288 1) 704x240 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x120 1) 80x60 1) 1) Not visible in web user interface