FIRMWARE RELEASE NOTES ====================== Products affected: AXIS Q1931-E Release date: 2015-03-13 Release type: Production Firmware version: 5.75.1.1 File name: Q1931_5_75_1_1.bin Preceding release: 5.55.4.1 AMC version: 7.1.2.1-2 Onvif support: Profile S ------------------------------------------------------------------------------ UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. New features ============ 5.75.1:F1 Firmware 5.75 extends the ACAP SDK which gives new possibilities to develop ACAP’s. It is also possible to enable multiple ACAP applications to run simultaneously. 5.75.1:F2 Axis is now extending SNMP with AXIS Video MIB (Management Information Base). The Video MIB enables notification of a number of possible disruptions in Axis products such as fan failure, temperature limits, storage disruptions, tampering, video/audio connectors disconnect, etc via SNMP traps. Available traps depend on the Axis product. A MIB is released for Axis products. See http://www.axis.com/techsup/software/index.htm for more information. 5.75.1:F3 Axis firmware now has the ability to auto-format an SD card to a specified file system upon insertion. This will allow an easy installation of a new SD card that will be formatted automatically to a preselected file system, mounted and recording will be resumed. 5.75.1:F4 Edge Storage recording makes it possible to indicate, e.g. on the Live view, that an edge storage recording is ongoing. This allows the operator to be notified if a recording of scene is ongoing or not. 5.75.1:F5 The Live View page is updated with responsive design and scales with different screen resolutions and browser window sizes. This will allow the user to always see the complete page without the need to scroll. 5.75.1:F6 The Export Video Clip capability enables the export of recordings directly from the camera to a PC or a smartphone. Select the wanted portion of an Edge Storage recording from your camera and export them as playable video file to a client. The exported recording will be one playable matroska file. 5.75.1:F7 SSH command line interface to the products that may be used for specific support and maintenance activities was introduced in 5.50. SSH is now the only supported protocol to establish a connection and telnet is not supported anymore. SSH is not enabled by default but can be activated by an API. 5.75.1:F8 Secure FTP (SFTP) is now supported allowing a more secure file transfer method. 5.75.1:F9 Edge Storage robustness is improved with features to detect and repair faults due to unexpected loss of storage media. 5.75.1:F010 Storage limit offers a possibility to control how much storage space may be used for recordings. This is available via VAPIX. 5.75.1:F011 Axis network cameras now support NAS drives over 2TB. 5.75.1:F012 Storage manager collects information about SD card usage. Corrections in 5.75.1.1 since 5.55.4.1 ========================================= 5.75.1:C01 Ongoing recordings will be accessible and possible to download from the web interface after a restart initiated in the web interface. 5.75.1:C02 Select "Use Temporary Mode" if temporary files during ftp upload is wanted. 5.75.1:C04 Privacy masks marking will be aligned to the marking regardless of capture mode and selected resolution when saving the settings. 5.75.1:C05 Improvements in setup of new video streaming towards network storage after longer connection disruptions. 5.75.1:C06 It is possible to use "Play from start" offset on the Play Recording page for ongoing recordings. 5.75.1:C07 All emails will include a final boundary when an Actioon rule is sending out multiple emails for one trigger. 5.75.1:C08 It's now possible to have recurrence in seconds. 5.75.1:C09 Startup time is not affected if a network share is mounted. 5.75.1:C10 Default resolution for quality stream profile will now use sensor size. 5.75.1:C11 Status led will now behave as described in user manual when upgrading the camera. Known Bugs/Limitations ====================== 5.75.1:L01 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.75.1:L02 90 and 270 rotation can cause a drop in frame rate. 5.75.1:L03 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.75.1:L04 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.75.1:L05 Reboot is necessary after changes to SOCKS such as enabling/disabling and parameter changes. 5.75.1:L06 When changing an active https-certificate, the product needs to be restarted for the new certificate to be applied. 5.75.1:L07 When upgrading to firmware 5.75, the Edge Storage database might take a couple of minutes to migrate to the new database system. Make sure not to remove power or SD card during the first few minutes after upgrading the device. Edge Storage recordings used with 5.75 products will not show recordings when downgraded to previous firmware. The recordings will however still be present on the card but not accessible. 5.75.1:L08 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.75.1:L09 To be able to seek in exported mkv recordings you need to use AXIS Matroska File Splitter, see axis.com. Files are playable both with and without AXIS Matroska File Splitter. 5.75.1:L10 If setting the video stream resolution to an unsupported value, it's not possible to start streaming without specifying a valid resolution or correcting the video stream resolution to a supported resolution. 5.75.1:L11 SNMP OID that have been set are not kept after reboot. 5.75.1:L12 Video motion detection will detect objects hidden behind privacy masks. 5.75.1:L13 Using special characters § ½ ! £ \ ” @ [ ] ’ $ ¤ {}& * ? ^¨~+ =´ ` < > | , ; : in the upload folder name will not work as expected. 5.75.1:L14 After uploading a new application, the installed applications list web page needs to be manually reloaded for it to be updated. 5.75.1:L15 For the Java Applet viewing to work with Java 7 update 51 and later add the camera URL to the exception list as per: http://www.java.com/en/download/help/java_blocked.xml 5.75.1:L16 It's not possible to set the RTPS timeout in the URL specifying the stream. The default value of 120 seconds will always be used. 5.75.1:L17 Exposure window may not give the expected behavior when using equalization. Supported AXIS VAPIX API Image Resolutions for AXIS Q1931-E ============================================================== Resolution Exceptions ========== ========== 768x576 640x480 480x360 384x288 320x240 240x180 160x120 720x576 640x512 320x256 160x128 176x144 704x576 1) 704x480 1) 704x288 1) 704x240 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x120 1) 80x60 1) 1) Not visible in web user interface