FIRMWARE RELEASE NOTE ===================== Products affected: AXIS Q1775 Release date: 2017-06-15 Release type: Production Firmware version: 7.20.1 File name: Q1775_7_20_1.bin Preceding release: 7.10.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New features in 7.20.1 since 7.10.1 ====================================================================== 7.20.1:F1 The functionality of enabling Axis DNS Service via control button has been disabled by default. It can be enabled again using VAPIX. 7.20.1:F2 Changed the default web server authentication from Basic & Digest to Digest only. 7.20.1:F3 Upon a factory default, the camera will generate a self-signed certificate at boot and enable HTTPS. This allows clients to use encrypted access from start. If HTTPS is to be used in daily operations, it is recommended to replace the generated self-signed certificate with a CA-signed certificate. 7.20.1:F4 Apache web server has been updated to version 2.4.25. 7.20.1:F5 Support for 24bit LPCM audio mode. 7.20.1:F6 OpenSSL has been updated to version 1.0.2k to increase overall minimum cyber security level. 7.20.1:F7 Support for AXIS SD card health API. The SD card health API allows a client to track and request the health and wear-out state of an camera with AXIS Surveillance SD Card. 7.20.1:F8 The Axis Media Control (AMC) is not longer embedded in the product and needs to be downloaded separately on https://www.axis.com/global/en/support/downloads /axis-media-control if needed. The Java Applet has been removed as well. 7.20.1:F9 Pressing "Download the server report" in System -> Maintenance will now automatically attach a snapshot of the image to the .zip file in order to simplify support. New features in 7.10.1 since 6.50.1 ====================================================================== 7.10.1:F1 It is now possible to specify image rotation via ONVIF video source configuration 7.10.1:F2 Axis Video Motion Detection (VMD) 4 replaces Axis VMD 3 as preinstalled application. 7.10.1:F3 VMD upgraded to version 4.1. 7.10.1:F4 Corrected Turkey/Istanbul timezone from GMT+2 to GMT+3. 7.10.1:F5 New web-interface with improved usability and broader support of web-clients and operating systems. For more information please see https://www.axis.com/global/en/support/technical-notes/browser-support. 7.10.1:F6 The new web-interface supports 12 different pre-installed languages which will be chosen automatically based on browser settings. Uploading individual language files is not needed anymore. Supported Languages: English - German - French - Spanish - Italian - Portugese - Polish - Russian - Japanese - Chinese (Mainland) - Chinese (Taiwan) - Korean Corrections in 7.20.1 since 7.10.1 ====================================================================== 7.20.1:C1 Corrected an issue that prevented the user from saving a action rule with a Email Recipient that had SSL enabled. 7.20.1:C2 Corrected a issue resulting in "503 Service Unavailable" when trying to play a recording from a camera with a specific time range via ONVIF. 7.20.1:C3 Corrected an issue with an additional sign "/" in the absolute upload path of an SFTP Recipient when saving the action rule causing it to not work correctly. 7.20.1:C4 Corrected an issue when an ONVIF client connected to the camera via digest authentication. 7.20.1:C5 Fixed critical vulnerability ACV-116267. 7.20.1:C6 Improved camera stability when recording via ONVIF profile G. Corrections in 7.10.1 since 6.50.1 ====================================================================== 7.10.1:C1 Corrected handling of #D text overlay, it's no longer needed to specify the camera source. 7.10.1:C2 Improved handling of day and night shift levels adjustment. 7.10.1:C3 Improved HTTP image upload stability in unstable networks. 7.10.1:C4 Improved camera stability when metadata is used. 7.10.1:C5 Improved loading of the web-interface in unstable networks. 7.10.1:C6 Improved camera stability when TriggerData is used. 7.10.1:C7 Corrected a bug in the event system that prevented the camera from re-sending the SMTP notification every 10 seconds in case the receiving server reported an error. 7.10.1:C8 Improved stability in actionengine (tcp notification). Known Bugs/Limitations ====================================================================== 7.20.1:L1 Recording streams to SD Card with total bit rate above 12Mbit/sec may cause missing frames/sequences. 7.20.1:L2 The following features in Settings -> System will be displayed in English only as for now: Certificates, ONVIF, HTTPS, IEEE 802.1x, SNMP, Events, Stream profiles and Detectors. The current chosen language will not have any affect there. 7.20.1:L3 It is recommended to perform a factory default after downgrading the cameras firmware if needed. 7.20.1:L4 Features currently explained in the help files may not be supported in the camera. 7.20.1:L5 Video streaming H.264 for Safari has been temporarily disabled in the web- interface because of an bug in the Safari browser. 7.20.1:L6 No audio support when viewing MJPEG video streams directly in the web-interface. However, a recorded video MJPEG video stream from the cameras storage can be played with audio using a 3rd party client e.g. Microsoft Windows Media Player. 7.20.1:L7 Camera is not inserting a new I-frame when a 2nd client requests a video stream via multicast through RTSP which results in additional waiting time before video streaming starts. 7.20.1:L8 Videos that have been recorded using the video capture feature in live view may not be playable in some media players (e.g. VLC) as it is in an fragmented MP4 format without total video duration. 7.10.1:L1 Parts of the web-interface will have only English as language. 7.10.1:L2 H264 support for Safari has been temporarily disabled in the web-interface because of an bug in the Safari browser. 7.10.1:L3 Axis Analytic ACAPs (VMD, CLD etc) will trigger on object behind privacy masks. To avoid this exclude areas needs to be added for the Analytic ACAPs. Supported AXIS VAPIX API Image Resolutions for AXIS Q1775 ========================================================= Resolution Exceptions ========== ========== 1920x1200 4) 1920x1080 2) 3) 1600x1200 4) 1400x1050 1280x960 1280x800 1280x720 1024x768 1024x640 800x600 854x480 800x500 800x450 640x480 640x400 640x360 480x360 480x300 480x270 320x240 320x200 320x180 240x180 160x120 160x100 160x90 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 80x50 1) 1) Not visible in web user interface 2) 1080p 1920x1080 (16:9) @ 25/30 fps (WDR) 3) 1080p 1920x1080 (16:9) @ 50/60 fps (no WDR) 4) WUXGA 1920x1200 (16:10) @ 25/30 fps (no WDR)