FIRMWARE RELEASE NOTE ===================== Products affected: AXIS P5515 Release date: 2016-04-20 Release type: Production Firmware version: 6.20.1.1 File name: P5515_6.20.1.1.bin Preceding release: 5.85.3 -------------------------------------------------------------------------------- Upgrade instructions ===================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New features ============ 6.20.1.1:F1 Edge storage recording robustness is improved with an automatic database repair feature. 6.20.1.1:F2 Support for the NTCIP ACAP. 6.20.1.1:F3 Auto-iris will be enabled after manual PTZ movement from a preset with manual iris settings. 6.20.1.1:F4 SNMP MIB r/w OID values are saved after reboot. 6.20.1.1:F5 Improved info in server report from software and hardware PoE detection/negotiation. 6.20.1.1:F6 Improved start-up time. 6.20.1.1:F7 Removed predefined stream profiles: Quality, HDTV, Balanced, Bandwidth, Mobile. 6.20.1.1:F8 Upgrade OpenSSL to version 1.0.2d. This version also provides support for TLS 1.2. 6.20.1.1:F9 Improved Axis Zipstream technology for PTZ cameras. Corrections ============ 6.20.1.1:C1 RTSP over TCP may cause choppy video if block size is not optimized or set during video connection. 6.20.1.1:C2 Improved SD card recording handling. 6.20.1.1:C3 ONVIF users are now handled when PTZ Control Queue is enabled. 6.20.1.1:C4 Exposure improvements when enabling custom exposure zones 6.20.1.1:C5 Fine tuning of IR cut filter switch in automatic mode 6.20.1.1:C6 Preview window is updated when changing Video Stream settings. 6.20.1.1:C7 Solve network share mount failures at startup. 6.20.1.1:C8 Improved handling of frequent I/O triggering. 6.20.1.1:C9 When DST is enabled, export recordings can now be done via web interface. 6.20.1.1:C10 It is now possible to a select starting point when playing back a recording while using multicast and H.264. 6.20.1.1:C11 PullMessages now follow the ONVIF specification 9.1.2. 6.20.1.1:C12 Rule is now triggered on startevent/"signal raise" and not on condition. 6.20.1.1:C13 Users with admin permissions can edit ACAP configuration settings. 6.20.1.1:C14 Camera is reached through HTTPS when NAT traversal is enabled. 6.20.1.1:C15 Improved Privacy mask alignment. 6.20.1.1:C16 Improved synchronization between sound and video when having low fps and long GOV length. 6.20.1.1:C17 An overlay text in Live View is displayed when the camera is performing pan/tilt calibration and additional logging functions has been added 6.20.1.1:C18 Product is shutting down PTZ functionalities for safety reason when pan/tilt calibration failed too many times. 6.20.1.1:C19 Improved response performance of GetCompatibleVideoEncoderConfigurations. 6.20.1.1:C20 Corrected H264 payloader behaviour to now insert PPS/SPS frames before every I-frame. This will improve behavior, especially with clients that uses multicast. 6.20.1.1:C21 Corrected image corruption issue seen in corridor format. 6.20.1.1:C22 Overview map removed when PTZ controls are disabled. 6.20.1.1:C23 Added ACAP support for NV12 format. Known Bugs/Limitations ============ 6.20.1.1:L1 When the automatic IR cut filter enables/disables the IR cut filter, it may trigger motion detection. 6.20.1.1:L2 Recording streams to SD card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 6.20.1.1:L3 When enabling the control queue while using Java applet as default viewer access to PTZ is denied. The PTZ tab that is usually available is not and so it is not possible to use either center mode or joystick mode. The PTZ bars still work and the control queue appears to work correctly. 6.20.1.1:L4 Embedded Motion Detection: When object size is set to low and sensitivity set to high, motion detection can occasionally be triggered when switching the IR filter on/off. 6.20.1.1:L5 Text modifiers #x #y #z #Z #L do not work for upload file/folder names, TCP/HTTP notification text or e-mail subject/message. 6.20.1.1:L6 Pan limits set using VAPIX are not reflected using ONVIF. 6.20.1.1:L7 Automatic gain setting needs to be configured to 42dB for the use of color optimized Day/Night switch priority setting, otherwise night mode will never trigger. 6.20.1.1:L8 Area of interest is not shown during reconfiguring of detectors created when the camera was configured with a different video rotation setting. 6.20.1.1:L9 Current iris setting indicator is not shown in automatic iris mode. Resolution Exceptions ========== =========== 1920x1080 1280x720 800x450 480x270 320x180 1280x960 1) 1024x768 1) 1024x576 1) 800x600 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 640x480 1) 640x400 1) 640x360 1) 480x360 1) 480x300 1) 384x288 1) 352x288 1) 352x240 1) 320x240 1) 320x200 1) 240x180 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x100 1) 160x90 1) 80x50 1) analyze 1) 1) Not visible in web user interface