FIRMWARE RELEASE NOTE ======================== Products affected: P3925-LRE Release date: 2021-04-15 Release type: Production Firmware version: 10.5.0 Preceding release: 10.4.0 -------------------------------------------------------------------------------- Upgrade recommendations ======================== When updating the device, it is recommended to do an intermediate upgrade using an available AXIS OS LTS-release on the way to the desired AXIS OS version. For example, if the device currently is running AXIS OS 7.40 and you want to upgrade to the latest AXIS OS Active Track (Example: 10.1, October 2020) then you should do the upgrade in these steps: 7.40 => 8.40 LTS => 9.80 LTS => 10.1. More detailed recommendations can be found in the AXIS OS portal at https://www.axis.com/support/firmware. Upgrade the firmware according to the instructions given in howtoupgrade.txt, which is included in the firmware folder or according to instructions at https://www.axis.com/support/firmware. NOTE ======================== For latest information about Axis Cybersecurity, see: https://www.axis.com/support/product-security New features in 10.5.0 ================================================================================ 10.5.0:F1 RTSP and HTTP stream URL:s now allow for filtering overlays based on overlay type. This is done by setting 'overlays=' in the URL (only one value). 10.5.0:F2 OpenSSL upgraded to 1.1.1j to fix CVE-2021-23841 and CVE-2021-23840. Features in 10.4.0 ================================================================================ 10.4.0:F1 Added support for new action "Publish MQTT", available in the web-interface in Events -> Device events -> Rules setup. This new action allows to publish MQTT messages with custom topic and payload. 10.4.0:F2 Added possibility to select which source should be shown by default in the web interface. To set, go to Settings -> System -> Plain config -> Layout -> Live view video, and select the number for the source. 10.4.0:F3 Successful and failed user login attempts are now logged in detail when the Access Log parameter is enabled from Plain Config -> System -> Access Log 10.4.0:F4 OpenSSL upgraded to 1.1.1i to fix CVE-2020-1971. Corrections in 10.5.0 ================================================================================ 10.5.0:C1 Increased the number of allowed characters for event condition name to 512. 10.5.0:C2 Corrected an issue that prevented the use of some special characters in ONVIF passwords. 10.5.0:C3 Corrected an issue that prevented the Axis device to respond with HTTP 403 Forbidden when the source-ip address was blocked when using PreventDOSAttack in Plain Config -> System. Previously HTTP 401 Unauthorized was returned. Corrections in 10.4.0 ================================================================================ 10.4.0:C1 Corrected an issue that erased the password from the MQTT broker connection settings when editing settings occasionally. This required the user to re-enter the password when this happened. 10.4.0:C2 Corrected an issue that caused the MQTT configuration in the device to get corrupt on rare occasions. 10.4.0:C3 Corrected an issue that could caused an MQTT event to be duplicated upon registering the same event multiple times. 10.4.0:C4 Updated digital input LogicalState metadata API to consistently use 0/1 on all camera models. 10.4.0:C5 Corrected an issue that caused the device to send an EPRT command when transferring an image or video via FTP instead of an EPSV command. 10.4.0:C6 Corrected an issue where a network share used as a recipient could get its properties overwritten by another network share created from the Storage page. 10.4.0:C7 Corrected an issue that required the user to re-enter the password for the user for the MQTT broker connection upon changing other MQTT settings. 10.4.0:C8 Corrected nice names for the PreventDoSAttack parameters in Settings -> System -> Plain Config-> System -> PreventDoSAttack. 10.4.0:C9 Improved Link Layer Discovery Protocol (LLDP) system stability. 10.4.0:C10 Corrected response for NTP API version. Known Bugs/Limitations ================================================================================ Supported AXIS VAPIX API Image Resolutions for P3925-LRE ================================================================================ Resolution Exceptions Capture mode ------------ ------------ -------------- 1920x1080 2) 1280x960 2) 1280x800 2) 1280x720 2) 3) 1024x768 2) 3) 1024x640 2) 3) 800x600 2) 3) 800x500 2) 3) 800x450 2) 3) 640x480 2) 3) 640x400 2) 3) 640x360 2) 3) 480x360 2) 3) 480x300 2) 3) 480x270 2) 3) 320x240 2) 3) 320x200 2) 3) 320x180 2) 3) 240x180 2) 3) 176x144 2) 3) 160x120 2) 3) 160x100 2) 3) 160x90 2) 3) 1440x1080 1) 2) 1440x900 1) 2) 1400x1050 1) 2) 1024x576 1) 2) 3) 768x576 1) 2) 3) 720x576 1) 2) 3) 704x576 1) 2) 3) 704x480 1) 2) 3) 704x288 1) 2) 3) 704x240 1) 2) 3) 384x288 1) 2) 3) 352x288 1) 2) 3) 352x240 1) 2) 3) 192x144 1) 2) 3) 176x120 1) 2) 3) 80x50 1) 2) 3) analyze 1) 2) 3) 1) Not visible in web user interface 2) 2MP 1920x1080 (16:9) @ 25/30 fps 3) 1MP 1280x720 (16:9) @ 45 fps