FIRMWARE RELEASE NOTE ===================== Products affected: M3016 Release date: 2018-09-19 Release type: Production Firmware version: 8.40.1 Preceding release: 8.30.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/tecnical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. New features in 8.40.1 ================================================================================ 8.40.1:F1 Renamed "Browser Stream Statistics" to "Client Stream Information". The Client Stream Information are available in the web-interface of the camera. 8.40.1:F2 Updated apache webserver to version 2.4.33 to increase overall minimum cyber security level. 8.40.1:F3 AXIS Video Motion Detection 4.2.5 is now pre-installed. 8.40.1:F4 Updated help files with more detailed information about SMB and Certificate support in AXIS products. 8.40.1:F5 Added a new section "Snapshot of current CPU utilization" that prints information about CPU utilization and memory consumption of processes in the server report. 8.40.1:F6 Changed the default timeout of HTTP-Recipient based action rules from 10s to 120s to compensate for unstable networks or slow clients. After the timeout is reached, the action rule will be re-tried. Features in 8.30.1 ================================================================================ 8.30.1:F1 Added the possibility for the user to share anonymous usage data with AXIS developers. 8.30.1:F2 Added support for automatically negotiating the preferred SMB protocol version with SMB 2.1 or higher in order to increase the overall minimum cybersecurity level. Please refer to the follwing FAQ for more information -> https://www.axis.com/support/faq/FAQ116392. In case SMB 1.0 or SMB 2.0 is required due to compatibility issues, we recommend setting the Extra Mount Options in PlainConfig -> Storage to a specific version"vers=x.y" (e.g vers=1.0 or vers=2.0). Please note that there are two Storage groups that are related to a mounted network share (normally Storage S1 and Storage S2) and both of them need to have the correct version in Extra Mount Options. 8.30.1:F3 Updated OpenEmbedded to version Poky Rocko to increase overall cyber security level. 8.30.1:F4 Updated the maximum number of recipients for action rules to 20 from 10. 8.30.1:F5 AXIS Video Motion Detection 4.2.4 is now pre-installed. 8.30.1:F6 Prepared support for signed firmware to increase overall cyber security level. It is planned that the product will only accept AXIS security-signed firmware starting in Q1/Q2 2019 and onwards. Corrections in 8.40.1 ================================================================================ 8.40.1:C1 Corrected an issue with incorrect handling of ACAPs after camera boot. 8.40.1:C2 Corrected an issue that prevented the user from formatting SD cards and the web- interface to show incorrect information about network share status in Settings -> System -> Storage. 8.40.1:C3 Added selection boxes for disabling TLSv1.0 and TLSv1.1 in Settings -> System -> PlainConfig -> HTTPS to enforce the highest possible TLS version for HTTPS-based connections. 8.40.1:C4 Corrected an issue that could cause a network share to become read-only. 8.40.1:C5 Corrected an issue that prevented the overlay to show the correct state of inputs when toggling. 8.40.1:C6 Corrected an issue in the ACAP framework that caused installed ACAPs to become unresponsive and the Apps tab not to be shown correctly. 8.40.1:C7 Corrected an issue that let the network share test under Events -> Recipient fail when a NAS was connected that only supports SMB 1.0 or SMB 2.0. 8.40.1:C8 Corrected an issue that caused the certificate signing request not to have an LF (alt. CR-LF) every 64th character causing the certificate considered not being valid e.g. when using symantec certificates. 8.40.1:C9 Corrected an issue that prevented the user from creating a Recipient when a "-" sign was present in the host name. 8.40.1:C10 Corrected an issue that could cause the configuration file upload from ADM to camera to fail. 8.40.1:C11 Corrected an issue that prevented the user to export recordings in the desired time range. 8.40.1:C12 Patched security vulnerability CVE-2018-5390 to increase overall minimum cyber security level. 8.40.1:C13 Patched security vulernability CVE-2018-14526 to increase overall minimum cyber security level. Corrections in 8.30.1 ================================================================================ 8.30.1.1:C1 Corrected an issue that caused the web-interface to show either none or wrong information about the network share status after mounting a share in Settings -> System -> Storage. Previously the user needed to refresh the browser page via F5 in order to get the correct information shown. 8.30.1.1:C2 Corrected an issue that caused AXIS Perimeter Defender or SafeZoneEdge to stop working after a firmware upgrade. 8.30.1.1:C3 Corrected an issue in the ACAP framework that caused installed ACAPs to become unresponsive on rare occasions and the Apps tab to not be shown correctly. 8.30.1.1:C4 #Affected Products #M5525-E Corrected an issue that prevented the camera from finding good focus on rare occasions. 8.30.1:C1 Corrected an issue that could display wrong possible maximum FPS in Settings -> Image. 8.30.1:C2 Corrected an issue that could cause the camera to get stuck in night mode when WDR setting changed. 8.30.1:C3 Corrected an issue that caused the camera to become unresponsive on rare occasions when running ACAPs without specified ApplicationId. 8.30.1:C4 Increased user awareness when converting legacy overlays to dynamic overlays. A restart of ongoing recordings is required after overlay conversion. 8.30.1:C5 Corrected an issue with the Axis event handling interface when deactivating events. 8.30.1:C6 Updated OpenSSL to version 1.0.2o to increase overall minimum cyber security level. Known Bugs/Limitations ================================================================================ 8.40.1:L1 It is recommend to refresh the browser with F5 after doing a FW upgrade from FW 6.xx to 8.xx or higher in order to show all the new settings in the web- interface. 8.30.1.1:L1 When using the Edge or Firefox web browser automatic license installation doesn't work as expected. 8.30.1.1:L2 Some parts of the web-interface may not be fully translated. 8.30.1.1:L3 It is not possible to update the product using Genetec 5.7 SR2. Genetec will provide a patch in 5.7 SR3. Supported AXIS VAPIX API Image Resolutions for M3016 ================================================================================ Resolution Exceptions ========== ========== 2016x1512 2) 2304x1296 3) 1920x1080 1280x960 1280x720 1024x768 1024x576 800x600 640x480 640x360 352x240 320x240 768x576 1) 704x576 1) 704x480 1) 384x288 1) 352x288 1) 1) Not visible in web user interface 2) 3MP (2016x1512) 3) 3MP 16:9 (2304x1296)