FIRMWARE RELEASE NOTE ===================== Products affected: AXIS F44 Release date: 2016-07-07 Release type: Production Firmware version: 6.30.1 File name: F44_6.30.1.bin Preceding release: 5.85.3 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New Features in 6.30.1 since 5.85.3 =================================== 6.30.1:F1 If Network Share is setup to use DNS host name as host and if the IP address changes after mount, the host name is resolved to current IP address. 6.30.1:F2 Added support for ONVIF standardised I/O events. 6.30.1:F3 Edge storage recording robustness is improved with an automatic database repair feature. 6.30.1:F4 Improved info in server report from software and hardware PoE detection/negotiation. 6.30.1:F5 Max exposure time parameter is now available in the Camera Settings. It can be used in LPR installations when setting Max exposure time shorter than default Max shutter time. 6.30.1:F6 SNMP MIB r/w OID values are saved after reboot. 6.30.1:F7 Stream synchronization between same type of sensor units, that use the same capture mode and FPS, i.e. images from two or more sensor units gets the same timestamp. 6.30.1:F8 WDR on at least one sensor unit with 720p and 15 fps. 6.30.1:F9 WDR is supported on multichannel products 6.30.1:F10 Improved start-up time. 6.30.1:F11 Removed predefined stream profiles: Quality, HDTV, Balanced, Bandwidth, Mobile. 6.30.1:F12 Upgrade OpenSSL to version 1.0.2d. This version also provides support for TLS 1.2. 6.30.1:F13 Improved Zipstream using dynamic frame rate. 6.30.1:F14 Support for ONVIF Profile G. Corrections in 6.30.1 since 5.85.3 ================================== 6.30.1:C1 Fixed a critical security vulnerability. 6.30.1:C2 Video loss bit set in trigger data when sensor unit is disconnected. 6.30.1:C3 Access to Zipstream settings is now available to Operators. 6.30.1:C4 PullMessages now follow the ONVIF specification 9.1.2. 6.30.1:C5 Possible to use custom stream profile as default in Live View 6.30.1:C6 From the web gui the rule is now triggered on startevent/"signal raise" and not on condition. 6.30.1:C7 Camera is reached through HTTPS when NAT traversal is enabled. 6.30.1:C8 Rectified pulsing of the image in very bright environment. 6.30.1:C9 Improved Privacy mask alignment. 6.30.1:C10 Fixed issue with image switching between black & white and color mode. 6.30.1:C11 Fixed issues with output buttons only working once in IE. 6.30.1:C12 Corrected H264 payloader behaviour to now insert PPS/SPS frames before every I-frame. This will improve behavior, especially with clients that uses multicast. 6.30.1:C13 Led pulse button can now be turned on in Internet Explorer. 6.30.1:C14 Corrected image corruption issue seen in corridor format. 6.30.1:C15 Fixed script error when naming a privacy mask with åäö. 6.30.1:C16 Added ACAP support for NV12 format. 6.30.1:C17 Improved performance in MOTE and ACAP’s when converting from UYVY to GRAY8(Y800). 6.30.1:C18 If the total bandwidth received from the camera is greater than 90 Mbps all streams might not get an equal share of the network cards maximum throughput. 6.30.1:C19 Fixed issues with stopped events for manual triggered recording. 6.30.1:C20 Date format now displayed correctly in ACM. 6.30.1:C21 Corrected issue with drifting over/under exposed images Known Bugs/Limitations ====================== 6.30.1:L1 The status LED is unlit during the boot-up sequence and then goes steady green when system is ready. 6.30.1:L2 RTSP over TCP may cause choppy video if block size is not optimized or set during video connection. 6.30.1:L3 Recording streams to SD card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 6.30.1:L4 Text overlays with video data in each stream will not be correct in quad view 6.30.1:L5 Setting a fixed shutter time on a channel to a high value, for instance 2s, the other streams in the quad channel are limited by this setting regardless what they are set to. 6.30.1:L6 Text modifiers #x #y #z #Z #L do not work for upload file/folder names, TCP/HTTP notification text or e-mail subject/message. 6.30.1:L7 When downgrading to an older firmware, the root password might be changed back to its default password. 6.30.1:L8 Capture mode change might require a camera restart to get full FoV. 6.30.1:L9 Using identical start and stop time for a scheduled event will never trigger an event. 6.30.1:L10 WDR button is not present on the Live View if a sensor unit without WDR capability is used in port one. 6.30.1:L11 Some special UTF-8 characters can not be used for privacy mask names. Supported AXIS VAPIX API Image Resolutions for AXIS F44 ======================================================= Resolution Exceptions ========== ========== 1920x1080 1280x720 1024x768 1024x640 800x600 854x480 800x500 800x450 640x480 640x400 640x360 480x360 480x300 480x270 1400x1050 1) 3) 960x540 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 320x240 1) 320x200 1) 320x180 1) 240x180 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x100 1) 160x90 1) 80x50 1) 1) Not visible in web user interface 2) Available on Quad channel 3) 1080p 1920x1080 (16:9) @ 15/12.5fps