NEW SOFTWARE RELEASE ==================== Products involved: AXIS 570, AXIS 670 Specific software: Release date: June 29 1998 Release type: TEST Software version: 5.45.1 Software media: AXIS 570 Flash AXIS 670 Flash Software checksum: AXIS 570 Flash AXIS 670 Flash Last preceding release: AXIS 570 5.45 AXIS 670 5.45 Flash loading instructions: See UpgrInfo.txt document Release document: 1.00 --------------------------------------------------------------------- NOTE: ===== The non SNA/IBM part of this release is based on Print Server software release 5.43. See Release Descriptions below for information on changes made to the non SNA/IBM parts of the software in the 5.43 release. --------------------------------------------------------------------- Easy Release Description: 1. Three more source bins added. 2. A change of CPI or FGID takes immediate effect also when printing in COR. 3. A problem with changing CPI in matrix printer emulation corrected. 4. Some problems with automatic orientation corrected. 5. CPI values used in COR printing are modified. Also six parameters for selecting CPI in COR printing added. 6. New page size limits for switching to/from COR. 7. A problem with permanently saving changes in string type parameters solved. 8. An IBM Emulator problem causing the last line in a job not to be printed has been solved. 9. A SNA/5494 autoconfiguration problem after AS/400 backup operations and/or IPL has been corrected. 10. A SNA/5494 autoconfiguration feature causing the printer devices to have VARY ON PENDING status if the printer is turned off or off-line has been removed. 11. Memory configuration information has been added on the testpage. This release is based on Print Server software release 5.43. The changes made in the 5.43 release is covered below: 1. The IP address, netmask, default router and trap address parameters can now be entered with dots between the numbers. 2. NetWare. Fixed a problem that prevented use of multiple queues in bindery emulation mode. 3. Fixed a problem that sometimes prevented the print server from announcing itself in NetWare. 4. Fixed a problem that sometimes prevented notification messages from being shown in NetWare NDS environments. 5. Status and accounting information is now updated periodically on the print server's internal web pages. 6. Configuration and management from the print server web pages don't require authentication if the root password is equal to the factory default value PASS. 7. Fixed a problem that made the print server hang sometimes when the IP address or net mask was changed during runtime. 8. Added support for HP OpenSpool. Now possible to print directly to the print servers IP address with LPR without having to specify a printer port. 9. Fixed a problem that prevented print servers with version 5.36 to appear in NetPilot if there was a router in between. 10. Fixed a problem causing the print server to hang sometimes when print jobs were canceled. 11. Improved reliability of flash loading. This applies to both FTP and IPX flash loading. 12. Fixed a problem that could cause infinite authentication pop-up messages when using MS Internet Explorer for configuration. Recommendation: - An update to this release is recommended if any problems, related to the above changes, have been observed. Best regards AXIS COMMUNICATIONS AB ---------------------------------------------------------------------- Appendix A - DETAILED TECHNICAL DESCRIPTION OF RELEASE App A Products involved: AXIS 570, AXIS 670 Software version: 5.45.1 1. The source bin parameters that handles manual feed paper, envelope feed and countiuous feed (BIN4, BIN5 and BIN6) are renamed to MANUAL, ENVELOPE and CONTINUOUS. The corresponding bin selection strings in the printer driver (BIN4S, BIN5S, and BIN6S) are renamed to MANUALS, ENVELOPES and CONTINUOUSS. Three new source bin parameters (BIN4, BIN5 and BIN6) and corresponding bin selection strings in the printer driver (BIN4S, BIN5S, and BIN6S) have been added. The PCL4 printer driver is equal to the PCL4 and PCL5 drivers in previous releases. The PCL5 driver can now handle six source bins plus manual, envelope and continuous feed. 2. When the host sends a CPI or FGID change command it will now take effect immediately also when printing in COR. 3. When the print server is configured for matrix printer emulation and the host changes CPI in the middle of a print line sometimes the CPI change took effect in the wrong place of the line. This problem is now corrected. 4. No further information. 5. New default values for CPIs used for COR printing. Added six parameters for selecting CPIs in COR printing. PORT/LAND COR New parameter ======================================= 5 CPI => 10 CPI 8 CPI => 12 CPI CPI8COR 13 CPI => 20 CPI 17 CPI => 20 CPI 18 CPI => 20 CPI 20 CPI => 20 CPI CPI20COR 25 CPI => 25 CPI CPI25COR 27 CPI => 27 CPI CPI27COR Proport. => 15 CPI PROPOCOR Typograph.=> 15 CPI TYPOCOR 6. The page size set in the selected input bin parameter (BIN1 - BIN6, MANUAL, ENVELOPE or CONTINUOUS) is used when the automatic orientation function is deciding whether the printout shall be in COR or not. 7. No further information. 8. In some cases the last line in a print job would not be printed until the next job was sent to the Print Server. This problem is now solved. 9. Interference from other devices on the network would in some cases lead to autoconfiguration failure after AS/400 restricted mode and/or IPL. The problem was related to the XID3 negotiation sequence between the Print Server and other devices on the network. This problem is now fixed. 10. If the printer was turned off or off-line this would be dectected by the Print Server and no information would be sent to the AS/400 about the attached printer(s). The printer devices on the AS/400 would be in VARY ON PENDING state until the printer was turned on and put on-line. Now, this is changed so the Print Server will always report a printer even of none is attached. 11. Memory configuration information has been added on the testpage. The information include the amount of both Flash and RAM memory. This release is based on Print Server software release 5.43. The changes made in the 5.43 release is covered below: 1. The IP address, netmask, default router and trap address parameters can now be entered in the format "aaa.bbb.ccc.ddd" in the configuration file. A space between each number will also work as before. 2. No additional information. 3. In some situations during start-up the print server did not send out necessary advertising information resulting in that the unit was not visible for a NetWare server. This problem is now solved. 4. In some situations the print server did not send notification messages when set up in NetWare NDS environments. This problem is now solved. 5. The status is updated every 5 seconds and the accounting page every 5 seconds. 6. No additional information. 7. If the IP-address or the subnet mask of the print server was changed while one or more reverse telnet port were configured (set to something else than 0), the print server could hang and would have to be manually restarted. 8. The print jobs sent using e.g. OpenSpool will be printed on the printer defined in the parameter DEF_OUT (accessed from NetPilot General property page, value "Internal Printout Destination"). 9. Software release 5.36 introduced a problem in the NetWare RIP protocol which prevented the print server from appearing in the list of servers on the file server when placed on the other side of a router. 10. When removing print jobs from the pending job list, the print server sometimes hang. This problem is now solved. 11. The flash loading is now more reliable. When upgrading a unit that has a software revision lower than 5.39, the flash loading could fail. For units with revision 5.39 or higher, flash loading is more robust. 12. When the authentication information was split in two packets the print server would not recognize the password. ---------------------------------------------------------------------- Appendix B - SOFTWARE LIMITATIONS App B Products involved: AXIS 570, AXIS 670 Software version: 5.45.1 1. The SNA stack is single host only. Multiple IBM hosts cannot access the Print Server simultaneously. 2. Although it is possible to define several logical units on the IBM host system, the AXIS 570/670 will only print one SNA job at a time. SNA Jobs are held in a print queue within the AXIS 570/670 and are processed on a first-come-first-served basis. 3. The SNA parameters LU_NAME and CP_NAME must be equal. ---------------------------------------------------------------------- Appendix C - AFFECTED MATERIAL App C 1( ) Product involved: AXIS 570, AXIS 670 Software version: 5.45.1 Draft texts for manual updates: NPS Technical Reference Support for editable character tables added and the text in "AXIS HP-MIO TECH REF 1.1 ADDENDUM Editable character translation" shall be inserted in the NPS Technical Reference. ---------------------------------------------------------------------- END OF RELEASE DOCUMENT.