FIRMWARE RELEASE NOTE ====================== Products affected: AXIS P3304 Fixed Dome Network Camera Release date: 2019-08-16 Release type: Production Firmware version: 5.51.6 Preceding release: 5.51.5.2 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/tecnical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. NOTE ==================== For latest information about Axis Cybersecurity, see https://www.axis.com/se/sv/support/product-security. Corrections in 5.51.6 since 5.51.5.2 ===================================== 5.51.6:C01 Improved robustness of the O3C client. 5.51.6:C02 Removed the root users default password in factory defaulted firmware. The password of the root user must be set first in order to initialize VAPIX and ONVIF interfaces to allow further configuration. This change only affects products in its factory defaulted state, products that are already deployed in production systems are not affected by this update until factory defaulted. Corrections in 5.51.5.2 since 5.51.5.1 ======================================= 5.51.5.2:C01 Corrected an issue that caused event notifications not been triggered on storage disruption. 5.51.5.2:C02 Improved re-connection behavior to AVHS server. The time between failed connection attempts will now gradually increase until a hard limit is reached. 5.51.5.2:C03 A user with administrator rights can now upload PTZ drivers for those cameras supporting this feature. Note that a factory default will be required to remove the old permissions sets from the firmware. 5.51.5.2:C04 Corrected an issue that caused an overload of the CPU after enabling IP adress filtering. 5.51.5.2:C05 Corrected common vulnerabilities in the Linux kernel to increase overall minimum cyber security level. CVE-2010-2960, CVE-2010-4175. 5.51.5.2:C06 Patched security vulernability CVE-2018-14526 in WPA supplicant to increase overall minimum cyber security level. Corrections in 5.51.5.1 since 5.51.5 ==================================== 5.51.5.1:C01 Corrected an issue that caused the action engine to respawn on scheduled triggered action events. 5.51.5.1:C02 Corrected an issue that caused SD cards to become full and write protected on rare occasions. Corrections in 5.51.5 since 5.50.5.4 ==================================== 5.51.5:C01 Updated R2 GlobalSign Root Certificate to version 20170717. 5.51.5:C02 Corrected an issue that let the camera become unresponsive in rare occasions when connected to an AVHS system. 5.51.5:C03 Corrected critical vulnerability ACV-128401. Known Bugs/Limitations ====================== 5.51.6:L01 To be able to use all parts of the image in a View Area use the 4:3 Aspect Ratio for the View Area. 5.51.6:L02 90 and 270 rotation can cause a drop in frame rate. 5.51.6:L03 Multiple simultaneous recordings to SD cards and network shares can degrade the performance of the system. 5.51.6:L04 Windows Network Shares do not handle all modifiers e.g. %c, since modifiers are UNIX standard. 5.51.6:L05 Frame Size Control does not affect the size of the snapshot taken with the upper right control that can be added to the Live View. 5.51.6:L06 If the device has ongoing continuous recordings and the device is restarted using the restart option in web interface, the current part of recordings(block) can not be accessed or downloaded through the web interface. 5.51.6:L07 Stream profile names are limited to alphanumerical characters. 5.51.6:L08 The AXIS Media Control client may stop displaying the H.264 video stream after the PC has been locked. 5.51.6:L09 Live view does not work with QuickTime player using default settings. Workaround: Disable Direct3D acceleration in Quicktime. 5.51.6:L10 When using an action rule results in short recordings, it is recommended to extend post-event time. 5.51.6:L11 For actions based on PTZ events, it is not possible to use the #P (PTZ preset name) and #p (PTZ preset number) modifiers in the file names for network share uploads. 5.51.6:L12 It's not recommended to downgrade to previous firmware when having HTTPS enabled. 5.51.6:L13 Modifying a PTZ view area using API and afterwards clicking save in the web interface, will cause the view area to revert to the old position. 5.51.6:L14 Time zone selection for Moscow Time is not correct according to the changes made to this time zone. 5.51.6:L15 If text overlay is more than 460 characters long, no text will be displayed. 5.51.6:L16 Private keys need to be in a PKCS#1 format in order to function. 5.51.6:L17 A maximum of 100 installed certificates is allowed 5.51.6:L18 For low contrast scenes, false positives or negatives may occur because there is not enough information for the Tampering alarm. 5.51.6:L19 If downgrading to previous firmware version, a factory default is recommended after performing the downgrade. 5.51.6:L20 Using control queue with Java Applet may result in wrong queue positions if switching between admin and viewer users. 5.51.6:L21 GOV values for stream profiles higher than 5000 are not supported. 5.51.6:L22 On Windows shares, upload paths for events needs to be created on the share before use. 5.51.6:L23 Not possible to view live or recorded video in Internet Explorer 10 Modern UI in Microsoft Windows 8. Supported AXIS VAPIX API Image Resolutions for AXIS P3304 ========================================================= Resolution Exceptions ========== ========== 1280x800 1280x720 1024x768 1024x640 800x600 800x500 800x450 640x480 640x400 640x360 480x360 480x300 480x270 320x240 320x200 320x180 240x180 176x144 160x120 160x100 160x90 1440x900 1) 768x576 1) 704x576 1) 704x480 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 192x144 1) 176x120 1) 1) Not visible in web user interface