FIRMWARE RELEASE NOTES ====================== Products affected: M7014/M7010 Release date: 2013-06-19 Release type: Production Firmware version: 5.50.2 File name: M7014_5_50_2.bin Preceding release: 5.40.7.1 AMC version: 6.2.10.12-1 Onvif support: Profile S ------------------------------------------------------------------------------ UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. New Features ============ 5.50.2:F01 Edge Storage Disruption Detection, ability to be notified when the Edge Storage detects disruptions that may need administrative attention, typically disk unavailable, read/write error, disk full or disk locked. 5.50.2:F02 Text Overlay character set extension, ability to use non-western characters in the video text overlay. Note that, Right-to-left languages such as Arabic are not supported. 5.50.2:F03 Text Overlay Font Size, ability to select three different font sizes for the video text overlay in order to increase readability, especially for high resolution video. 5.50.2:F04 ONVIF Profile S conformance. The ONVIF Profile S replaces the ONVIF Version 1.02. 5.50.2:F05 Text Overlay Message Action, a camera action that provides a way to display a user defined message in the image's text overlay upon a detected event. 5.50.2:F06 Email/SSL Recipient, ability for the camera to connect to common email services. The camera includes predefined profiles for example, Gmail and Hotmail. 5.50.2:F07 HTTPS Recipient, systems using HTTP notifications from the camera can now do this in a secure way over HTTPS. 5.50.2:F08 Upload Video Clip Action, ability to upload a video clip to an FTP server or an email recipient upon an event. Note that, a media player with support for H.264 and Matroska File Format (MKV) is required to play the clip. 5.50.2:F09 Live Stream Access Detection, it is now possible to notify people that someone is actively monitoring a camera. 5.50.2:F10 Edge Storage Device Redundancy, ability to automatically switch recording device between SD Card and NAS if one device detects disruption. 5.50.2:F11 Virtual Inputs, used by clients to initiate Action Rules in the camera. Virtual Inputs extends the existing "Manual Trigger" with 32 additional. 5.50.2:F12 Centralized Certificate Management, certificates for HTTPS and 802.1x are now managed in one place. The firmware also includes a number of pre-installed CA certificates such as Verisign, Thawt and GeoTrust. 5.50.2:F13 Improved Constant Bitrate Control, the Constant Bit Rate (CBR) will now adjust to target bit rate quicker. 5.50.2:F14 SSH (Secure Shell), a command line interface is added to the camera that may be used for specific support and maintenance activities. Note that, SSH is not enabled by default. 5.50.2:F15 Edge storage with support for CIFS/SMB (Microsoft Network share). 5.50.2:F16 Server Report download. Possibility to download a ZIP-file server report (with or without camera snapshot). This simplifies the process of attaching the server report when submitting a support ticket. Corrections in 5.50.2 since 5.40.7.1 ========================================= 5.50.2:C01 Daylight saving time now works properly for Iran. 5.50.2:C02 ISO 8859-1 characters are displayed correctly in motion detection names and OSDI zone names. 5.50.2:C03 Up to 127 characters can be used in the 'From email address' field. 5.50.2:C04 It is possible to add IP addresses to the IP filter list in the web interface. 5.50.2:C05 When a PTZ VAPIX call to ptz.cgi is done with several commands including the unsupported ones, the correct commands will be executed instead of being discarded. 5.50.2:C06 It is now possible to use HTTPS and port forwarding. 5.50.2:C07 It is no longer necessary to restart the camera after configuring default router parameter via VAPIX. 5.50.2:C08 Configuration of time zone for Australia appears correctly in the web interface. 5.50.2:C09 Double & (&&) are no longer present in HTTP notifications. The Action rule gives a valid URI. 5.50.2:C10 ONVIF: The Web Services parameter and consequently the information in System Overview relating to whether Web Services is enabled has been removed. ONVIF is enabled by specifying an ONVIF administrator in Security > ONVIF settings. 5.50.2:C11 Accessing the AVHS portal through a proxy is now working. 5.50.2:C12 Date modifiers "%m-%d-%Y" are now formatted correctly when used with folder name, SMTP subject and message. 5.50.2:C13 Corrected an issue that could block PTZ control completely which required a reboot of the camera to make it possible to control it again. 5.50.2:C14 The error condition encountered when creating two similar action rules (or by a copied action rule) has been fixed. 5.50.2:C15 Network share size will now be displayed as GB if less than TB in the web interface. 5.50.2:C16 Pelco drivers are now pre-loaded for using PT motors or PTZ camera through RS485. 5.50.2:C17 Setting Always multicast TTL (Time To Live) to '0' is now working as expected. 5.50.2:C18 Fixed behavior for serial cgi “writestring=”. 5.50.2:C19 Use of IPs starting with 169.154.x.x is now properly reserved for link-local addresses. 5.50.2:C20 The #e modifier now displays proper event names. 5.50.2:C21 The Edge Storage disc utilization has been improved, this will also result in increased video retention time especially for larger discs. 5.50.2:C22 The default compression value has been changed, it is tuned more effectively to provide more flexibility for video applications in a wide variety of network environments. To revert to old setting, configure the camera to use compression=26. 5.50.2:C23 Issue where incorrect multicast addresses were used, has been corrected. 5.50.2:C24 It is now possible to use 169.254.x.x as a static IP. 5.50.2:C25 Correct network speed is now displayed when using SNMP network speed check. 5.50.2:C26 The Log message 'RTSP Login Failed' that relates to client RTSP commands after the nonce has expired has been removed, since the behavior is correct. 5.50.2:C27 Fixed an issue with the Axis Name Service and some router models. Known Bugs/Limitations ====================== 5.50.2:L01 Zoom is shown on live view page when using java applet as default viewer, even though it is not supported. 5.50.2:L02 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.50.2:L03 90 and 270 rotation can cause a drop in frame rate. 5.50.2:L04 Multiple simultaneous recordings to SD cards and network shares can degrade the performance of the system. 5.50.2:L05 Windows Network Shares do not handle all modifiers e.g. %c, since modifiers are UNIX standard. 5.50.2:L06 When Guard Tour is active, it is not possible to use PTZ controls with Viewer access rights. 5.50.2:L07 If the device has ongoing continuous recordings and the device is restarted using the restart option in web interface, the current part of recordings(block) can not be accessed or downloaded through the web interface. 5.50.2:L08 Stream profile names are limited to alphanumerical characters. 5.50.2:L09 Recordings made with firmware earlier than 5.20 will not be readable on the SD Card from firmware 5.40 and onward. Backup important recordings and reformat the SD Card after the firmware upgrade. 5.50.2:L10 Check and repair is only available if the file system is ext4. 5.50.2:L11 The AXIS Media Control client may stop displaying the H.264 video stream after the PC has been locked. 5.50.2:L12 Live view does not work with QuickTime player using default settings. Workaround: Disable Direct3D acceleration in Quicktime. 5.50.2:L13 When using an action rule results in short recordings, it is recommended to extend post-event time. 5.50.2:L14 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.50.2:L15 For actions based on PTZ events, it is not possible to use the #P (PTZ preset name) and #p (PTZ preset number) modifiers in the file names for network share uploads. 5.50.2:L16 Downgrading from 5.50.x to a 5.40.x firmware version will cause an AVHS/O3C connection to drop. Do not downgrade an AVHS/O3C connected camera unless you can do a factory reset locally on the camera. 5.50.2:L17 It's not recommended to downgrade to previous firmware when having HTTPS enabled. 5.50.2:L18 Video overlay text size is a global setting and can not be set for each stream profile. 5.50.2:L19 If text overlay is more than 460 characters long, no text will be displayed 5.50.2:L20 Private keys need to be in a PKCS#1 format in order to function. 5.50.2:L21 The resolutions of the pre-defined profiles have changed. Quality, Balanced and Bandwidth uses default resolution, which is equal to the highest available resolution. Mobile uses the lowest resolution. 5.50.2:L22 If downgrading to previous firmware version, a factory default is recommended after performing the downgrade. 5.50.2:L23 For network share passwords, the character comma (,) is not allowed. 5.50.2:L24 Not possible to view live or recorded video in Internet Explorer 10 Modern UI in Microsoft Windows 8. 5.50.2:L25 Extented Driver Specific settings are missing under PTZ, Advanced, Device settings. Parameters are available in plain configuration. 5.50.2:L26 Using Java applet as a viewer, the button Zoom Wide does not zoom out fully. 5.50.2:L27 Unclear error message when uploading audio clip with already existing name. Supported AXIS VAPIX API Image Resolutions for AXIS M7010/M7014 =============================================================== Resolution Exceptions ========== ========== 16CIF 1536x1152 2) 4) 1280x960 3) 4) XGA 1024x768 4) D1 720x576 2) 720x480 3) 4CIF 704x576 2) 704x480 3) 2CIF 704x288 2) 704x240 3) CIF 352x288 2) 352x240 3) QCIF 176x144 2) 176x120 3) VGA 640x480 1) analyze 1) 1) Not visible in web user interface 2) PAL mode resolution 3) NTSC mode resolution 4) Available on Quad channel