FIRMWARE RELEASE NOTE ====================== Products affected: M5013 Release date: 2021-11-23 Release type: Production Firmware version: 5.51.7.6 Preceding release: 5.51.7.5 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/technical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. NOTE ==================== For latest information about Axis Cybersecurity, see https://www.axis.com/se/sv/support/product-security. Corrections in 5.51.7.6 since 5.51.7.5 ======================================= 5.51.7.6:C01 Corrected an issue in ftptest.cgi and smtptest.cgi that caused "502 Bad Gateway" error response. This was introduced in the 5.51.7.5 release. Corrections in 5.51.7.5 since 5.51.7.4 ======================================= 5.51.7.5:C01 Corrected CVE-2021-31987. 5.51.7.5:C02 Updated OpenSSL to version 1.1.1l to increase overall minimum cybersecurity level. 5.51.7.5:C03 Added an option to Disable or Enable TLSv1.0 or TLSv1.1 using param.cgi. [IPAddress]/axis-cgi/admin/param.cgi?action=update&root.HTTPS.AllowTLS1=no and [IPAddress]/axis-cgi/admin/param.cgi?action=update&root.HTTPS.AllowTLS11=no 5.51.7.5:C04 Corrected CVE-2021-31988. Corrections in 5.51.7.4 since 5.51.7.3 ======================================= 5.51.7.4:C01 Updated OpenSSL to version 1.1.1k to fix CVE-2021-3449 and CVE-2021-3450. 5.51.7.4:C02 Updated pwdgrp.cgi to be RFC compliant to work seamlessly with Home Assistant Systems. Corrections in 5.51.7.3 since 5.51.7.2 ======================================= 5.51.7.3:C01 Corrected an issue introduced in 5.51.7.2 that caused system instability. Corrections in 5.51.7.2 since 5.51.7 ===================================== 5.51.7.2:C01 Corrected a newline character in pwdgrp.cgi, introduced in 5.51.6, that could cause problems when parsing the response. 5.51.7.2:C02 Corrected an issue that prevented Action Rule Events from sending images via email. 5.51.7.2:C03 Corrected an issue that caused monolith to timeout and respawn during too many connect/disconnect RTSP streaming requests. 5.51.7.2:C04 Added support to enable/disable X-Frame-Options headers in the plainconfig. By default, X-Frame-Options is enabled and its value is set to "sameorigin". Corrections in 5.51.7 since 5.51.6.2 ===================================== 5.51.7:C01 Added possibility to retrieve the device Owner Authentication Key (OAK) in the web GUI. Note that this functionality requires that the product have direct access to the internet. 5.51.7:C02 Updated the wpa-supplicant to version 2.9 to increase the overall cybersecurity level. The following cybersecurity vulnerabilities are fixed: CVE-2019-13377 CVE-2019-16275. 5.51.7:C03 Updated OpenSSL to 1.1.1d to increase the overall cybersecurity level. 5.51.7:C04 Added support for TLSv1.2. 5.51.7:C05 Updated the client-side URL transfer library (libcurl) to version 7.53.1 to increase the overall cybersecurity level. Corrections in 5.51.6.2 since 5.51.6.1 ======================================= 5.51.6.2:C01 Corrected an issue that caused admin users other than root not to be allowed to change user account passwords. 5.51.6.2:C02 Added ProxyDispatcherOnly option to the O3C/AVHS client that can control proxy configurations of dispatcher services. 5.51.6.2:C03 Corrected an issue that caused camera to drop network connection when using 5.51.6.1 firmware. 5.51.6.2:C04 Added support for NAS over 2TB. Corrections in 5.51.6.1 since 5.51.6 ===================================== 5.51.6.1:C01 Added “X-Frame-Options: sameorigin” to the HTTP Response Headers in order to increase overall minimum cybersecurity level 5.51.6.1:C02 Updated Turkey (Istanbul) timezone to GMT +3. 5.51.6.1:C03 Improved robustness of the O3C client. Corrections in 5.51.6 since 5.51.5.2 ===================================== 5.51.6:C01 Improved robustness of the O3C client. 5.51.6:C02 Removed the root users default password in factory defaulted firmware. The password of the root user must be set first in order to initialize VAPIX and ONVIF interfaces to allow further configuration. This change only affects products in its factory defaulted state, products that are already deployed in production systems are not affected by this update until factory defaulted. Corrections in 5.51.5.2 since 5.51.5.1 ======================================= 5.51.5.2:C01 Corrected an issue that caused event notifications not been triggered on storage disruption. 5.51.5.2:C02 Improved re-connection behavior to AVHS server. The time between failed connection attempts will now gradually increase until a hard limit is reached. 5.51.5.2:C03 A user with administrator rights can now upload PTZ drivers for those cameras supporting this feature. Note that a factory default will be required to remove the old permissions sets from the firmware. 5.51.5.2:C04 Corrected an issue that caused an overload of the CPU after enabling IP adress filtering. 5.51.5.2:C05 Corrected common vulnerabilities in the Linux kernel to increase overall minimum cyber security level. CVE-2010-2960, CVE-2010-4175. 5.51.5.2:C06 Patched security vulernability CVE-2018-14526 in WPA supplicant to increase overall minimum cyber security level. Corrections in 5.51.5.1 since 5.51.5 ==================================== 5.51.5.1:C01 Corrected an issue that caused the action engine to respawn on scheduled triggered action events. 5.51.5.1:C02 Corrected an issue that caused SD cards to become full and write protected on rare occasions. Corrections in 5.51.5 since 5.50.3.10 ===================================== 5.51.5:C01 Updated R2 GlobalSign Root Certificate to version 20170717. 5.51.5:C02 Corrected an issue that let the camera become unresponsive in rare occasions when connected to an AVHS system. 5.51.5:C03 Corrected critical vulnerability ACV-128401. Known Bugs/Limitations ====================== 5.51.6.1:L01 The camera can not play an audio clip while a viewer is sending/receiving audio from to/from the camera. 5.51.6.1:L02 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.51.6.1:L03 Multiple simultaneous recordings to SD cards and network shares can degrade the performance of the system. 5.51.6.1:L04 Windows Network Shares do not handle all modifiers e.g. %c, since modifiers are UNIX standard. 5.51.6.1:L05 Frame Size Control does not affect the size of the snapshot taken with the upper right control that can be added to the Live View. 5.51.6.1:L06 If the device has ongoing continuous recordings and the device is restarted using the restart option in web interface, the current part of recordings(block) can not be accessed or downloaded through the web interface. 5.51.6.1:L07 Stream profile names are limited to alphanumerical characters. 5.51.6.1:L08 Check and repair is only available if the file system is ext4. 5.51.6.1:L09 The AXIS Media Control client may stop displaying the H.264 video stream after the PC has been locked. 5.51.6.1:L10 Live view does not work with QuickTime player using default settings. Workaround: Disable Direct3D acceleration in Quicktime. 5.51.6.1:L11 When using an action rule results in short recordings, it is recommended to extend post-event time. 5.51.6.1:L12 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.51.6.1:L13 For actions based on PTZ events, it is not possible to use the #P (PTZ preset name) and #p (PTZ preset number) modifiers in the file names for network share uploads. 5.51.6.1:L14 It's not recommended to downgrade to previous firmware when having HTTPS enabled. 5.51.6.1:L15 Video overlay text size is a global setting and can not be set for each stream profile. 5.51.6.1:L16 If text overlay is more than 460 characters long, no text will be displayed. 5.51.6.1:L17 Private keys need to be in a PKCS#1 format in order to function. 5.51.6.1:L18 A maximum of 100 installed certificates is allowed 5.51.6.1:L19 If downgrading to previous firmware version, a factory default is recommended after performing the downgrade. 5.51.6.1:L20 Using control queue with Java Applet may result in wrong queue positions if switching between admin and viewer users. 5.51.6.1:L21 GOV values for stream profiles higher than 5000 are not supported. 5.51.6.1:L22 On Windows shares, upload paths for events needs to be created on the share before use. 5.51.6.1:L23 Not possible to view live or recorded video in Internet Explorer 10 Modern UI in Microsoft Windows 8. 5.51.6.1:L24 Time zone selection for Moscow Time is not correct according to the changes made to this time zone. 5.51.6.1:L25 Reboot is necessary after enabling SOCKS. 5.51.6.1:L26 With audio enabled, setting GOV lengths with I-frames more than 20 seconds apart may render the recordings unplayable via the web interface. 5.51.6.1:L27 When changing active https-certificate, the device needs to be restarted before it becomes active. 5.51.6.1:L28 Upgrading from firmware 5.40 and prior requires an upgrade of the recordings database. This can take up to five minutes and is conducted on first boot. Make sure to not remove power or SD card during the first five minutes after upgrading the device. 5.51.6.1:L29 Occasionally, G711 audio can lag when using Java applet. 5.51.6.1:L30 Embedded Motion Detection: When object size is set to low and sensitivity set to high, motion detection can occasionally be triggered when switching the IR filter on/off. Supported AXIS VAPIX API Image Resolutions for AXIS M5013 ========================================================= Resolution Exceptions ========== ========== 800x600 800x450 640x480 640x360 480x360 480x270 320x240 320x180 768x576 1) 720x576 1) 704x576 1) 800x500 1) 704x480 1) 640x400 1) 704x288 1) 704x240 1) 480x300 1) 384x288 1) 352x288 1) 352x240 1) 320x200 1) 240x180 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x100 1) 160x90 1) 80x50 1) 1) Not visible in web user interface