Continuous pan
On Daiwa DMP15-H1 units continuous pan movements will stop after 360 degress if they are not refreshed with a different speed

Video Source Configuration

Parameter Description Range
Device ID ID for the connected device, this is set on the rotary DIP-switches. 0-254

Driver Specific Settings

There are no driver specific settings for this driver.
Mechanical limits

Movement Limits Minimal value Maximal value Comment
Left -180 180 Limits how far the unit is allowed to move. This affect both absolute, relative and continuous movements. Useful for making sure that the unit doesn't collide with stationary objects
Right -180 180 Limits how far the unit is allowed to move. This affect both absolute, relative and continuous movements. Useful for making sure that the unit doesn't collide with stationary objects
Up -180 180 Limits how far the unit is allowed to move. This affect both absolute, relative and continuous movements. Useful for making sure that the unit doesn't collide with stationary objects
Down -180 180 Limits how far the unit is allowed to move. This affect both absolute, relative and continuous movements. Useful for making sure that the unit doesn't collide with stationary objects
Light Control

There are no light control settings for this driver.
Extended Driver Specific Settings

There are no extended driver specific settings for this driver.