FIRMWARE RELEASE NOTE ======================== Products affected: Q1951-E / Q1952-E Release date: 2021-09-29 Release type: Production Firmware version: 10.7.1 Preceding release: 10.7.0 -------------------------------------------------------------------------------- Upgrade recommendations ======================== When updating the device, it is recommended to do an intermediate upgrade using an available AXIS OS LTS-release on the way to the desired AXIS OS version. For example, if the device currently is running AXIS OS 7.40 and you want to upgrade to the latest AXIS OS Active Track (Example: 10.1, October 2020) then you should do the upgrade in these steps: 7.40 => 8.40 LTS => 9.80 LTS => 10.1. More detailed recommendations can be found in the AXIS OS portal at https://www.axis.com/support/firmware. Upgrade the firmware according to the instructions given in howtoupgrade.txt, which is included in the firmware folder or according to instructions at https://www.axis.com/support/firmware. NOTE ======================== For latest information about Axis Cybersecurity, see: https://www.axis.com/support/product-security Features in 10.7.0 ================================================================================ 10.7.0:F1 ACAPs containing a manifest.json file are now fully supported. The manifest.json file contains settings and parameters for the application. The older package.conf file is still supported. 10.7.0:F2 Added support for .ogg and .opus encoded mediaclips. 10.7.0:F3 Net-SNMP is now the new SNMP backend for AXIS OS devices and will replace the legacy SNMP backend that was used previously. Net-SNMP provides significant higher security mechanism and authentication for SNMPv3 than previously could be provided. 10.7.0:F4 Added support for MQTT subscription. With this support, it will be possible to use incoming MQTT messages as action triggers in the rule engine of the new preview web GUI. 10.7.0:F5 Added support for a new parameter, "root.SNMP.NTCIP.Enabled", that can be used to enable NTCIP. Please remove the NTCIP ACAP after upgrading to AXIS OS 10.7 or higher and enable NTCIP from Plain Config -> SNMP. 10.7.0:F6 Extended the 802.1x EAP-Identity field character limit from 32 to 128 characters. 10.7.0:F7 Added optional API status property in VAPIX API Discovery JSON response body. 10.7.0:F8 Updated Apache to version 2.4.48 to increase overall cybersecurity level. 10.7.0:F9 Updated OpenSSL to version 1.1.1l to increase overall minimum cybersecurity level. 10.7.0:F10 Updated Video Motion Detection to version 4.5.1. Fixed a streaming issue on configuration web page on some products. 10.7.0:F11 AXIS Motion Guard 2.3.0 is preinstalled. Fixed a streaming issue on configuration web page on some products. 10.7.0:F12 AXIS Fence Guard 2.3.0 is preinstalled. Fixed a streaming issue on configuration web page on some products. 10.7.0:F13 AXIS Loitering Guard 2.3.0 is preinstalled. Fixed a streaming issue on configuration web page on some products. Corrections in 10.7.1 ================================================================================ 10.7.1:C1 Corrected a network issue that on rare occasions could cause the product to lose its internet-connection. Corrections in 10.7.0 ================================================================================ 10.7.0:C1 Corrected CVE-2021-31986. 10.7.0:C2 Corrected CVE-2021-31987. 10.7.0:C3 Corrected CVE-2021-31988. 10.7.0:C4 Corrected an issue that prevented legacy motion detection from working. 10.7.0:C5 Corrected an issue with MQTT subscriptions when reconnecting. 10.7.0:C6 Corrected MQTT default message so it no longer starts with an empty string. 10.7.0:C7 Corrected an issue that caused the "Anonymous viewer" functionality to be removed after upgrade to 10.6.0. 10.7.0:C8 Corrected an issue that interrupted the NTP-time-sync between the Axis device and NTP-server when the NTP-server was operating instable and suffered fluctuating time-changes. 10.7.0:C9 Audio now uses the new audiodevicecontrol.cgi instead of the old API. This means that the gain values may be different in the GUI, but the actual audio level should be the same as before. 10.7.0:C10 Corrected an issue that prevented the Sound Intelligence Sound Detector ACAP to get an audio stream. 10.7.0:C11 Improved RTP timestamp accuracy for metadata streams. 10.7.0:C12 Corrected an issue that could cause an RTSP stream to stop after 60+ seconds if streamed to an openRTSP client. Known Bugs/Limitations ================================================================================ Supported AXIS VAPIX API Image Resolutions for Q1951-E / Q1952-E ================================================================================ Resolution Exceptions Capture mode ------------ ------------ -------------- 800x600 3) 768x576 2) 720x576 2) 3) 640x512 2) 3) 640x480 2) 3) 480x360 2) 3) 384x288 2) 3) 320x256 2) 3) 320x240 2) 3) 240x180 2) 3) 176x144 2) 3) 160x128 2) 3) 160x120 2) 3) 768x576 1) 3) 704x576 1) 2) 3) 704x480 1) 2) 3) 704x288 1) 2) 3) 704x240 1) 2) 3) 352x288 1) 2) 3) 352x240 1) 2) 3) 192x144 1) 2) 3) 176x120 1) 2) 3) 80x60 1) 2) 3) 1) Not visible in web user interface 2) QVGA (384 x 288) 3) VGA (640 x 480)