FIRMWARE RELEASE NOTES ====================== Products affected: AXIS P5522 PTZ Dome Network Camera Release date: 2012-03-21 Release type: Production Firmware version: 5.25.1 File name: P5522_5_25_1.bin Preceding release: 5.25 AMC version: 5.9.9.0-1 ------------------------------------------------------------------------------ UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. RELEASE 5.25.1 ============== 5.25.1 is a production service release for AXIS P5522. Corrected problems ================== 5.25.1:C01 Corrected the SSP/PPS H264 parameters time stamps, now it will be the same as the following I-frame. 5.25.1:C02 Socket leak during Guard Tour which caused the camera to slow down. 5.25.1:C03 Ethernet driver and streaming fixes added, should correct some cases where the camera was left unresponsive. 5.25.1:C04 LLDP broadcasts the proper MAC address. 5.25.1:C05 Improved SHTTP client. 5.25.1:C06 Center command with specified image height works properly. Known limitations ================= 5.25.1:L01 Audio clip upload size limit, limited to less than ~1.5MB. 5.25.1:L02 Motion detection reacts to IR cut filter. 5.25.1:L03 PKCS#12 with encrypted certificates are not time verified. 5.25.1:L04 SNMP test 5.4.0.1 fails over IPv6. 5.25.1:L05 SNMPv3 SilverCreek 4.20.8 (IPv6). 5.25.1:L06 RTSP clients timeout when syncing unit to computer time. 5.25.1:L07 Cannot record audio clip with no wait time. 5.25.1:L08 Error when removing micro SD card without unmounting it first. 5.25.1:L09 Criticals found in system log at restart when Guard tour is running. 5.25.1:L10 Control panel hidden behind the video sometimes. 5.25.1:L11 After a factory default,the default PTZ home position not defined when the PTZ framework is told to go to the home position; the the camera will remain at the calibration point. 5.25.1:L12 6.2.24 - Onvif failing test case: "This is due to a bug in the test tool and test specification, i.e. the Axis interpretation is correct. 5.25.1:L13 No warning message in log when pre-trigger buffer is too large. 5.25.1:L14 ONVIF speed param is ignored by the camera. 5.25.1:L15 MJPG recordings to SD card with too high bitrate may cause oom kill of monolith. 5.25.1:L16 Relative tilt applied despite tilt control being disabled when Auto-flipping. 5.25.1:L17 From time and duration not respected in continuous recording <5 min; Cue points not available until a MKV-file is finalized. 5.25.1:L18 Guard Tour View time is longer than stated in setup due to Focus/Iris taking some extra time. Application Developer Information ================================= The AXIS VAPIX Application Programming Interface version 3 is supported by the AXIS P5522. Supported AXIS VAPIX API Image Resolutions for AXIS P5522 Resolution Exceptions ========== ========== D1 720x576 1) 720x480 2) 4CIF 704x576 1) 704x480 2) 2CIF 704x288 1) 704x240 2) CIF 352x288 1) 352x240 2) QCIF 176x144 1) 176x120 2) 1) Only available for 50Hz cameras 2) Only available for 60Hz cameras 90/270 degress rotation is not supported.