FIRMWARE RELEASE NOTE ====================== Products affected: AXIS M1025 Network Camera Release date: 2017-12-07 Release type: Production Firmware version: 5.50.5.13 File name: M1025_5_50_5_13.bin Preceding release: 5.50.5.12 -------------------------------------------------------------------------------- Upgrade instructions ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. Corrections in 5.50.5.13 since 5.50.5.12 ======================================== 5.50.5.13:C01 - Affects Encoders Only - Corrected an issue that let the encoder to become unresponsive in rare occasions when disconnecting an analog camera. 5.50.5.13:C02 Corrected an issue of missing triggered data in H264 streams in rare occasions. 5.50.5.13:C03 Corrected security vulnerability CVE-2017-13077. 5.50.5.13:C04 Adjusted the image when configuring motion detection and the camera is configured with corridor format. 5.50.5.13:C05 Updated the Portable UPnP SDK to version 1.6.22. 5.50.5.13:C06 Corrected an issue that caused SNMP MIB r/w OID values not to be saved after a reboot. 5.50.5.13:C07 - Affects PTZ products only - Corrected an issue on the Gatekeeper setup webpage occurring during Step 3. 5.50.5.13:C08 Corrected security vulnerability CVE-2016-2147. Known Bugs/Limitations ====================== 5.50.5.13:L01 To be able to use all parts of the image in a View Area, use the same Aspect Ratio for the View Area as for your Capture Mode or Resolution. 5.50.5.13:L02 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.50.5.13:L03 90 and 270 rotation can cause a drop in frame rate. 5.50.5.13:L04 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.50.5.13:L05 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.50.5.13:L06 Using control queue with Java Applet may result in wrong queue positions if switching between admin and viewer users. 5.50.5.13:L07 The ipv6.class field will have the same value in all IPv6 packages. The class field value depends on the value of the DSCP setting. 5.50.5.13:L08 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.50.5.13:L09 Custom Exposure windows is not visible in Chrome and Firefox. Please use Internet Explorer. 5.50.5.13:L10 Longer connection disruptions towards the Network storage during playback of a recording from the Network storage may affect the possibilities to setup new video streaming also some time after reconnection. Ongoing live streaming will not be affected. 5.50.5.13:L11 To be able to seek in exported mkv recordings you need to use AXIS Matroska File Splitter, see axis.com. Files are playable both with and without AXIS Matroska File Splitter. 5.50.5.13:L12 SNMP OID that have been set are not kept after reboot. 5.50.5.13:L13 Once "Custom" Exposure Windows is chosen within the Java Exposure applet the browser login window keeps asking for credentials until you use root as login credentials. 5.50.5.13:L14 A combination of a high bandwidth continuous recording and a lot of small recordings can result in disc full. The automatic clean up will stop at the point and the user have to manually remove recordings. 5.50.5.13:L15 Number of different configured video streams is limited by hardware. 5.50.5.13:L16 I/O triggers need to be at least one second long for the device to accept the trigger. The minimum signal detection value can be changed in Plain Config for legacy support. 5.50.5.13:L17 When using a rotated overlay (90 or 270 degrees) and a large overlay text size simultaneously, the maximum allowed size of an overlay image is reduced to about 12 kB. 5.50.5.13:L18 The recordings database is not backwards compatible. A reformat of the SD-card is needed when installing older firmware. A reformat is also recommended when moving a SD-card from one camera to another. Supported AXIS VAPIX API Image Resolutions for AXIS M1025 ========================================================= Resolution Exceptions ========== ========== 1920x1080 2) 1280x1024 2) 1280x960 2) 1280x720 1024x768 2) 1024x640 3) 800x600 640x480 640x400 3) 640x360 480x360 352x240 320x240 768x576 1) 704x576 1) 3) 704x480 1) 3) 384x288 1) 352x288 1) 3) 1) Not visible in web user interface 2) Only for 1080p capture mode 3) Only for 720p capture mode